24/7 Automation Support
Line down, unfamiliar system, 2 a.m. — we send people who figure it out. It’s why the second call comes to us too.
The work
An automation emergency is not an electrical emergency.
The power is on, the panel is energized, and the process still won’t run — a failed I/O card, a corrupted program, a drive fault nobody can clear, a network that dropped a node. Diagnosing that needs someone who can go online with the PLC, not someone with a multimeter.
Most of the time we’ve never seen the machine. It was built by an OEM we don’t know, on a platform that’s twenty years old, with drawings that stopped matching the panel two modifications ago. That’s the job. Our technicians go online with the PLC, read the logic, find the fault, and get the line running — and plants notice, because the second call comes to us too.
Where we built the system, we start further ahead: programs, drawings and network topology are already on file, and where remote access is configured we can often be looking at the fault within minutes — saving valuable production dollars. Either way, every request runs through our ticket system: you know which technician is coming and when, you can follow progress in real time, and the service report afterward includes what we found, before-and-after photos, and what we’d recommend changing.
Typical scope
- 24/7 · 365 controls coverage, not business hours
- Any manufacturer, any platform, any vintage
- Technicians who diagnose from the logic, not just the drawings
- PLC, HMI, drive and network fault-finding on site
- Remote diagnostics where access exists
- Ticketed dispatch with notifications and escalation
- Technician identity and arrival time confirmed up front
- Before-and-after photos and a written service report with recommendations
- Systems we built: programs and drawings already on file
- Standing support agreements for covered sites
The fastest fix is often a migration — Legacy System Upgrades →
How a call runs
From the phone ringing to the report in your inbox.
Every request goes through our ticket system, so you know who is coming, when, and what they found.
Call
1-800-517-8512, any hour. A controls technician takes the call — not an answering service.
Ticket
The request is logged and you get the ticket. Where we have remote access, diagnosis starts here.
Dispatched
You’re told which technician is coming and when they’ll arrive. Across Southern Ontario, 1 to 1.5 hours in an emergency.
On site
Online with the PLC, reading the logic, finding the fault. You can follow progress on the ticket in real time.
Report
What we found, before-and-after photos, and what we’d recommend changing — filed to the ticket and sent to you.
What we support
Any manufacturer. Any vintage.
We’re not experts in every platform. We are experts at finding the fault.
| Allen-Bradley | Siemens | Other manufacturers | |
|---|---|---|---|
| PLCs | PLC-5, SLC 500, MicroLogix, CompactLogix, ControlLogix, GuardLogix | LOGO!, S7-200, S7-300, S7-400, S7-1200, S7-1500 | Schneider, Omron |
| HMIs | PanelView Plus, ArmorView Plus, MobileView | TP177B, KTP / KP / TP Basic and Comfort | Ignition, AVEVA / Wonderware, FactoryTalk View |
| Networks | EtherNet/IP, DH+, DeviceNet, ControlNet, Modbus, Profibus, serial RS-232 / 485, ASCII | Profibus, Profinet, MPI, PPI | CAN bus, IO-Link (Balluff, IFM), Modbus TCP / RTU |
| Drives | PowerFlex 755T, 753, 755, 70, 700; PowerFlex 523, 525, 527, 4, 40, 400 | Micromaster 410 / 440, Sinamics G120, Sinamics S120 | Schneider drives and soft starters; ABB drives and soft starters |
| Software | Studio 5000, RSLogix 5000 / 500, Connected Components Workbench, FactoryTalk View SE / ME / Studio, FactoryTalk Historian, ThinManager, DriveTools SP, PanelBuilder 32, RSView32 | TIA Portal V13 – V17, Simatic Manager, Step 7-MicroWIN, WinCC Flexible 2008 | Festo remote I/O, sensors and actuators; IFM sensors; Cognex vision |